Skip to main content
Version: Version 2.1.0

Governor setup

There are several options for configuring the Governor.

Governor Options

Single profile - Multiple throttle settings

Configuring a single profile with Full Headspeed set to the Maximum desired headspeed.

Governor Setup

Transmitter throttle settings are configured to Separate throttle positions for each desired headspeed.

Example: If we configure a 2500RPM Full headspeed

On the transmitter set the required headspeeds.

  • Throttle Hold = 0%
  • Idle up 1 = 70% = 2500 * 0.7 = 1750 RPM headspeed
  • Idle up 2 = 90% = 2500 * 0.9 = 2250 RPM headspeed
  • Idle up 3 = 100% = 2500 RPM Headspeed

This Method is easier to configure and simplifies the tuning as there is only one profile to change. You will have to tune so that it is suitable for each of the headspeed.